he radial turbine measurement principle is a method used to measure the volumetric flow of gas in various applications. This instrument offers a wide range of applications since, depending on the configuration, the measured flow rates range from 3 to 650 650 m³/h. To provide the output signal, low-frequency pulses are generated, in the case of a reed sensor, or high-frequency pulses, in the case of a NAMUR sensor allowing for greater accuracy in readings.
The process connection of these quantometers is via a flange in sizes DN 50, DN 80 and DN 100, or via a G 1½" or G 2" thread. This flexibility in connection allows for easy integration with existing systems.
The device can operate at temperatures up to 60°C, ensuring reliable measurement even in high temperature environments. The maximum supported pressure is 6 bar, making it suitable for various industrial applications.
In addition, the device has a PTFE coating to ensure compatibility with biogas and biomethane.
Product features
Detection type - Continuous measurement
Measurement type - With contact
Optional - None
Details of the signal inputs and outputs
All signal outputs available - Pulses
Output details - None
Electrical data
Reverse polarity protection - No
Approvals
Standards and Certifications - ISO 9001-2008 directive
CE omologation - Yes
Atex details - II 2G Ex ia IIB T4X
Logistics
Type of packaging - Carton BOX
Contains batteries - No