The system is intended for non-contact scanning and inner diameter measurement of objects having two through-holes of different diameter.
Measurement range (1st hole): 15...40 mm
Measurement range (2nd hole): 50...70 mm
Accuracy (1st hole): ±0,02 mm
Accuracy (2nd hole): ±0,005 mm
Resolution: 6400 point/turnover