The Atex heating jacket is recommended to optimize the LPG supply in domestic or industrial environments.
The external temperature or the strong supply of gas can cause the tank to freeze, resulting in difficulty in gas leakage
Application on tanks requires the use of several modules (3.000l tank-3 heating bands / 4.000l – 4 heating bands / 5.000l -5 heating bands).
LARGE TANKS HEATER TECHNICAL DATA (EACH ELEMENT):
Temperature management: 60° not adjustable double thermostat (temperature reached by the electric blanket).
75°C Thermal fuse
Power supply : 230Vac
Aramid fabric inside and outside
Internal thermal insulation of 1 cm in not flamabel material
Metallic layer connected to ground
Certifications: CE, ATEX EX II 3G IIB T3