HV Probes for Oscilloscopes, Digital Meters & Recorders
The Ross VMP high voltage probe with it's OSHA safety complying HV insulated handle accurately measures high voltage with as low as 0.1% DC and 0.5% AC accuracy, wideband, DC to 1MHz up to as high as 10MHz when matched with the appropriate meter or oscilloscope. Voltages can be read at a convenient 1000:1 ratio or 10,000:1 ratio. Other ratios or multiple ratios also available. Ideal for power supply DC voltage and ripple measurements, pulse viewing and measurement with waveform display, measuring or recording device. Ross collapsible insulated handle "Hot Stick" is supplied according to OSHA recommendations to maintain the proper clearance between HV and personnel. Insulated 100kV per ft for protection, the Ross "Hot Stick" handles easily connect to the VMP probe as well as collapse to fit into an optional protective carrying case.
Hand held probes 5kV PK to 400kV PK and base mounted high accuracy compensated wideband voltage dividers for both indoor and outdoor use from 5kV to 1,000kV DC or PK AC are available. Also available are base mounted high voltage precision Voltage Dividers to ±.01% DC and 0.2% 50/60Hz. Allow 8 weeks for delivery. Specify Power class RMS or Electronic Class DC or PK AC operate voltage, ratio, length of coaxial output cable, instrumentation load input resistance and capacitance, DC and/or AC accuracy and frequency range desired. Complete voltmeters, display recording and fiber optic transmission systems are available.