Test equipment "Elegas" is to test aerosol and combined filters of full face and half-masks, half-masks with valves and non-removable anti-gas filters, and filtering self-rescuers with persons according to EN 149, EN 13274-8, EN 136, EN 1827, EN 12941 and EN 12942.
Operation:
Test equipment determines the total inward leakage (TIL) of sulfur hexafluoride under the front part of the masks, bypassing the filter along the obturation strip, through the exhalation and inhalation valves, and through the leaky connections of the mask. During the test, the coefficient of SF6 leakage under the front of the mask to its content in the chamber atmosphere is calculated.
Features:
Universal platform for research & quality control of RPE:
suitable for most tests according to international standards, and in case of changes or new ones, you do not have to partially or completely replace the equipment; the settings are simply and flexibly changed in the software. In addition, it will allow you to conduct your research tests
Modern way of control:
no more manual switching; control of the SF6 concentration, direction, and speed of the airflow inside the chamber is done entirely through an application on a PC.
Saves time for lab staff:
the software automatically:
• measurement of SF6 concentration and the duration of the inhalation and exhalation phases in the pulse mode of sampling from the front of the RPE
• calculation of the coefficient of SF6 leakage when the person performs each exercise
Ergonomic design:
made of plexiglass for more comfortable environment for the person inside, and communication with him is established through the speaker system built into the treadmill