Microprocessor based domestic carbon monoxide detector with facility for the drive of cut-off valves, fans or any other electricalactuators with 230V~ power supply. Carbon monoxide detection with threshold mode. Not compliant with EN 50291.
TECHNICAL FEATURES
Power supply 230V~ -15/+10% 50Hz
Output (tight relay) 6(2)A @ 250V~ SPDT
Internal sensor Electrochemical cell
Button Alarm Test-Reset
Alarm Buzzer 85dB(A) @ 1m.
Pre alarm threshold 16ppm
Alarm threshold 80ppm
Green LED indicator Detector active
Yellow LED indicator Detector failure
Red LED indicator Alarm
Dimensions H84 W148 D40mm