Features
aseptic measuring point
closed off to process area
optional with head transmitter 4…20 mA
FDA, EHEDG conform
probe made of raw material No. 1.4301
Technical specifications
1 xPt100 class A
process connection: immersion probe with 3/8” union cap
standard range of application -10ºC to +150ºC
maximum permissible temperature for electronics up to 70ºC
connection with M12-connector
measuring tube: DA = 3.00 mm, EL 85.0 mm
threaded connection G 3/8” SW 19
material: G 3/8” screw and barstock: 1.4404/1.4301/1.4305
housing: 1.4301/1.4305
accuracy of measurement MU: max ±0.2v. final value
supply voltage: 10…35V (DC)
maximum process pressure 170 bar at 20ºC 130 bar at150ºC
outlet: 4…20mA, two-wire
protection class IP 69K
immersion pocket
material 1.4404
temperature range of application -100ºC to +250ºC