Features
level-limit switch for aqueous and oily substances
turn-on and shut-off thresholds selectable via software (not necessary to have 2 devices)
standard: aqueous substances
weld-in sleeve system and modular process connections
aseptic measuring point
medium-affected components are made of Peek
particularly high measurement dynamics
partially cast
FDA, EHEDG conform
Technical specifications
stainless steel terminal head material Nr. 1.4305
connection: M12-connector
thread G1/2” elastomer-free seal system
CIP- / SIP cleaning 0…150ºC (30 min)
supply voltage 20…32 VDC
output signal PNP (standard), NPN or Push-Pull reversible / break contact, turnkey reversible
start-up delay < 0.3s
response time <0.2s
ambient temperature -10…+70ºC
permissible substance temperature permanent 0…+100ºC
storage temperature -20…+70ºC
operating pressure max. 10 bar (higher pressures upon request)
protection class up to IP68 /69K
tightening torque 5…20 Nm
permitted electrical load: 100mA