Wisman's XEL Series of regulated x-ray high voltage power supplies offers output voltages to 50kV and incorporate a filament supply which provides regulated DC current adjustable between 0.3A and 3.5A at 5.5V. High voltage and filament current can be linearly ramped up. Wisman's XEL series x-ray generator can be taken easily and incorporates local and remote programming, monitoring, safety interlock, short-circuit ,arc and overload protection.
APPLICATIONS
X-ray tubes
Capacitor charging
Industrial equipment
Electronic components aging
Insulation testing
Electrophoresis
Electrostatic applications
Lasers
Scientific research.
SPECIFICATIONS
Voltage control:
Local: Internal multi-turn potentiometer to set voltage from 0 to full output voltage.
Remote: 0 to +10Vdc proportional from 0 to full output voltage. Accuracy: ±1%. ZIN: 10Mohm.
Local: The multi-turn potentiometer can set the electron beam current from 0A to the highest current.
Remote: The external 0 to 10V control signal can set the electron beam current from 0A to the highest current.
Voltage regulation :
Relative load: 0.01% (no load to rated load)
Relative input: ±0.01% (input voltage change is ±10%)
Current regulation:
Relative load: 0.01% (no load to rated load)
Relative input: ±0.01% (input voltage change ±10%).