Differential pressure transmitter FD3051S DP
4-20 mAModbus RTUHART

Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART - image - 2
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART - image - 3
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART - image - 4
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART - image - 5
Differential pressure transmitter - FD3051S DP - Shandong Friend Control System Co., Ltd. - 4-20 mA / Modbus RTU / HART - image - 6
Add to favorites
Compare this product
 

Characteristics

Pressure type
differential
Output
4-20 mA, HART, Modbus RTU
Process connection
NPT 1/2
Fluid
for liquids
Protection level
explosion-proof, IP65, IP66
Other characteristics
remote
Pressure range

Min.: 0 Pa
(0 psi)

Max.: 3,000,000 Pa
(435.11 psi)

Precision

0.08 %, 0.1 %, 0.5 %

Long-term stability

0.1 %

Process temperature

Min.: -20 °C
(-4 °F)

Max.: 80 °C
(176 °F)

Description

Wide measuring range,measure level, density, pressure/differential pressure and flow in fluids The sensor adopts digital compensation and nonlinear correction IP65 protection design,suitable for field,open air and other harsh environments Laser marking nameplate,the appearance is exquisite and meticulous Meet the requirements of GB3836 standard and with explosion-proof certificate. Digital circuit design,on-site button key reset Adjustable turndown ratio up to 100:1 FD3051S DP is suitable to measure liquid,gas,or steam flow as well as liquid level, density and pressure.FD3051S outputs a 4~20 mADC signal corresponding to the measured differential pressure.Its highly accurate and stable sensor can also measure the static pressure which can be shown on integral indicator or remotely monitored via HART communications. Key features include quick response, remote set-up using communications,self-diagnostics and optional status output for pressure high/low alarm.

Catalogs

FD3051S DP
FD3051S DP
1 Pages