Polarographic oxygen sensor DOG-208FA
analogppm levelfor wastewater

Polarographic oxygen sensor - DOG-208FA - Shanghai Boqu Instrument Co.,Ltd. - analog / ppm level / for wastewater
Polarographic oxygen sensor - DOG-208FA - Shanghai Boqu Instrument Co.,Ltd. - analog / ppm level / for wastewater
Polarographic oxygen sensor - DOG-208FA - Shanghai Boqu Instrument Co.,Ltd. - analog / ppm level / for wastewater - image - 2
Polarographic oxygen sensor - DOG-208FA - Shanghai Boqu Instrument Co.,Ltd. - analog / ppm level / for wastewater - image - 3
Polarographic oxygen sensor - DOG-208FA - Shanghai Boqu Instrument Co.,Ltd. - analog / ppm level / for wastewater - image - 4
Add to favorites
Compare this product
 

Characteristics

Technology
polarographic
Output
ppm level, analog
Other characteristics
process, for medical applications, real-time, in-line, for wastewater, high-temperature
Measuring range (%)

Max.: 200 %

Min.: 0 %

Description

DOG-208FA electrode, which is specially designed to be resistant to 130 degrees steam sterilization, the pressure auto-balance high temperature dissolved oxygen electrode, for liquids or gases dissolved oxygen measurement, the electrode is most suitable for small microbial culture reactor dissolved oxygen levels on line. Can also be used for environmental monitoring, waste water treatment and aquaculture on-line measurement dissolved oxygen levels. Dissolved oxygen electrode characteristics 1. DOG-208FA high temperature fermentation dissolved oxygen electrode applicable for Polarographic Principle 2. With imported breathable membrane heads 3. Steel gauze electrode membrane and silicone rubber 4. Endure high temperature, No deformation characteristics 1. Electrode body material: stainless steel 2. Permeable membrane: fluorine plastic, silicone, stainless steel wire mesh composite membrane. 3. Cathode: platinum wire 4. Anode: silver 5. Electrodes built-in temperature sensor: PT1000 6. The response current in the air: About 60nA 7. The response current in a nitrogen atmosphere: less than one percent response current of response in air. 8. Electrode response time: about 60 seconds (up 95% response) 9. Electrode Response Stability: a constant oxygen partial pressure at a constant temperature environment, response current drift less than 3% per week 10. Liquid mixing flow to the electrode response: 3% or less (in water at room temperature) 11. Electrode Response Temperature Coefficient: 3% (greenhouse) 12. Insert the electrode diameter: 12 mm, 19 mm, 25 mm optional 13. Electrode insertion length: 80,150, 200, 250,300 mm