MAGYN Series Electromagnetic Flowmeter conducts measurement based on the principle of the Faraday Electromagnetic Induction Law. When conductive liquid flows in a magnetic field and incises the magnetic flux, Induced electromotive force E will be generated in the conductor, as follows:
E=kBDV
Where,
B----------Magnetic induction density
k-----------Instrument constant
V----------Average velocity in the cross section of a measured pipe
D----------Inner diameter of a measured pipe
When measuring flow rate, the conductive liquid flows at a velocity of V perpendicularly through a magnetic field, which inducts a voltage that is direct proportional to the average velocity. The inducted voltage signal is measured on two or more poles immediately contacted with the liquid, sent to a convertor through the cable, and then intelligentized before it is transferred to and displayed in a LCD or converted into 4-20mA or 0-1kHz output.
Feature And Usage
*Independence: When the temperature, pressure, viscosity and density of the measured
fluid changing, the flowmeter will not be influenced.
*Easy Maintenance: No moving parts in measuring tube, so easy maintenance.
*Wide Application: Can measure conductivity liquid, Without reference to fibre, solid or suspending material contained in liquid.
*Easy Installation: Install any angle only need liquid full of the pipe. Straight pipe requires 5D for upper stream and 2D for down stream
*Turndown Ratio: The turndown ratio can reach to 1: 100
*Enclosure: For DN15-DN1200 is IP68
*High Intelligence: Back light English/Chinese LCD display, Menu setting control,