- High precision electrochemical sensor
- Multiple signal output, HART communication interface, multiple wire connection, infrared remote control or magnetic rod adjustment and calibration, easy to operate
- Pluggable intelligent sensor module, easy to replace
- Double recognition of explosion-proof in explosive gas environment and combustible dust environment
- Automatic zero setting, automatic fault identification and automatic error prompt
DETECTION PRINCIPLE -
Electrochemical
DETECTION METHOD - Diffusion
ACCURACY - ≤±3%F.S.
REPEATABILITY - ≤±3%F.S.
DISPLAY TYPE -
LCD display, LED indication
ALARM TYPE - LED light alarm, Ex-proof audible and visual alarm (optional)
ADJUST METHOD - Infrared remote controller, magnetic bar
POWER SUPPLY - 24VDC(15~30VDC)
POWER CONSUMPTION - ≤3W (with Ex-proof audible and visual alarm ≤5W)
CABLE CONNECTION - ≤1000m,3(4)×1.5mm2
OUTPUT SIGNAL -
4~20mA(three wires)
Relay output (2A 30VDC)
24VDC relay output (for audible and visual alarm);
MODBUS / RS 485(optional)
4~20mA+HART (optional)
ELECTRICAL INTERFACE - NPT3/4″(F) (Other size is available as request)
OPERATION TEMPERATURE - -40℃~+70℃ (according to the spec. of the sensor)
OPERATION HUMIDITY - 0~99%RH/Non condensation
EX-PROOF CERTIFICATE - Ex d ⅡC T6 Gb / Ex tD A21 IP66 T80℃
INGRESS PROTECTION - IP66
INGRESS PROTECTION -
Aluminium Alloy/ Stainless Steel
OUTLINE DIMENSIONS - 140×203×100mm(WxHxD)
WEIGHT
2,000g (Aluminium Alloy housing)