- Vacuum ceramic tube photo-ionization detection (PID)technology
- With built-in temperature –humidity sensor , with real-time temperature , humidity compensation function
- With built-in multiple response factors, easy for measuring the specific VOCs gas
- Modular design, easy for maintenance and replacement
- With built-in high performance micro vacuum pump internally installed, quick response, short recovery time
- Measuring data will be saved automatically and can be downloaded to PC
- With switchable mg/m3 and ppm unit
- With external filtering device installed, easy for maintenance and replacement
- With alarm history records, with real-time STEL, TWA and other data
- With intrinsic safety EX-proof certificate, can be used in hazardous area zone 0
Detection gas - Volatile organic compounds (VOCs), such as benzene, toluene, nitrobenzene, aniline, TDI, naphthalene, ketones, butadiene, ammonia and amines, etc.
Detection principle - Photo ionization (PID)
Detection method - Pump suction
Response time -
T90≤15S
Environment temperature - -30℃~+60℃
Relative humidity - 0~99%RH/non-condensing
Sensor life - ≥3 years
Explosion-proof mark - Ex id ⅡC T4 Gb
Display method -
Dot matrix LCD, LED indication
Alarm method - LED flashing alarm and sound alarm, alarm volume 90dB@30cm)
Pump flow - 250mL/min (with clogging alarm function)
power supply - Rechargeable intrinsically safe explosion-proof lithium electromagnetic group
Continuous working time - 20 hours (ambient temperature 20℃)
Weight - 500g
Dimensions - 70*300*50mm (WxHxD)
Protection grade - IP65