Over-current protection relay SIPROTEC 7SJ8 series
frequencytransmission linefor feeder

Over-current protection relay - SIPROTEC 7SJ8 series - SIEMENS Energy automation and smart grid - frequency / transmission line / for feeder
Over-current protection relay - SIPROTEC 7SJ8 series - SIEMENS Energy automation and smart grid - frequency / transmission line / for feeder
Over-current protection relay - SIPROTEC 7SJ8 series - SIEMENS Energy automation and smart grid - frequency / transmission line / for feeder - image - 2
Add to favorites
Compare this product
 

Characteristics

Measured/monitored value
over-current, frequency
Applications
for feeder, transmission line
Other characteristics
digital, programmable, differential, configurable, compact, high-voltage

Description

The overcurrent and feeder protection relays can be used for line/feeder protection of high and medium-voltage networks with grounded, low-resistance grounded, isolated or a compensated neutral point. The relays have all the required functions to be applied as a backup relay to a transformer differential relay. Features Hardware •4 current transformers •0/3 voltage transformers •3/7/11 binary inputs (thresholds configurable using software) •5/8 binary outputs (2 changeover / form C contacts) •1 life contact •Pluggable current and voltage terminals. Functions •Definite and inverse time-overcurrent protection (phase/ground) (50, 50N, 51, 51N) •Directional time-overcurrent protection (phase/ground) (67, 67N) •Directional sensitive ground fault protection (67Ns, 50Ns) •Overvoltage protection, zero-sequence system (59N) •High-impedance restricted ground-fault protection (87N) •Inrush restraint •Trip-circuit supervision (74TC) •Undercurrent monitoring (37) •Overload protection (49) •Undervoltage/overvoltage protection (27/59) •Forward-power, reverse-power protection (32) •Power factor (55) •Overfrequency/underfrequency protection(81O/U) •Circuit-breaker failure protection (50B/F) •Intermittent ground fault protection •Directional intermittent ground fault protection (67Ns) •Unbalanced-load protection (46) •Phase-sequence-voltage supervision (47) •Voltage dependent inverse-time overcurrent protection (51V) •Synchrocheck (25) •Automatic reclosing (79) •Fault locator (FL) •Lockout (86) •Rate-of-frequency-change protection (81R) •Rate-of-voltage-change protection (27R/59R)

Catalogs

No catalogs are available for this product.

See all of SIEMENS Energy automation and smart grid‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.