Process gas analyzer OXYMAT 6
oxygenmonitoringpressure

Process gas analyzer - OXYMAT 6 - Siemens Process Analytics - oxygen / monitoring / pressure
Process gas analyzer - OXYMAT 6 - Siemens Process Analytics - oxygen / monitoring / pressure
Process gas analyzer - OXYMAT 6 - Siemens Process Analytics - oxygen / monitoring / pressure - image - 2
Add to favorites
Compare this product
 

Characteristics

Measured entity
oxygen, process gas
Application domain
monitoring
Measured value
pressure
Technology
paramagnetic
Protection level
IP65, SIL 2
Other characteristics
continuous, extractive

Description

The OXYMAT 6 also meets the high standards in demanding applications through modern electronics, ease of operation, and a physical element that is adapted to the measurement task. Even for the smallest measuring ranges The SIL 2 classification obtained by OXYMAT 6 makes it easier for plant operators to comply with the often required proof of risk reduction. The OXYMAT 6 measures oxygen using the paramagnetic alternating pressure method. This guarantees perfect linearity and enables parameterization of smallest measuring ranges from 0 to 0.5% (detection limit 50 ppm) up to 0 to 100%, and even 99.5 to 100% in a single device. High-quality materials in the gas channel even enable the analytical devices to be used for measurements of corrosive gas mixtures. The detector unit has no contact with the measuring gas, thus allowing it to be used under harsh conditions while guaranteeing a long service life at the same time. Long lifetime Gas-tight separation of the electronic and physical components when using the field analyzer design with class IP65 protection and a purging gas connection guarantees a long lifetime even under harsh ambient conditions. Moreover, the field device design is also the basic variant for the optional heating feature of the analysis unit for measuring any low-boiling components and for use in hazardous zones Max. number of components 1 Minimal measuring range 0-0,5 % Housing field housing Paramagnetic alternating pressure method: Small measuring ranges (0 to 0.5% or 99.5 to 100% O2), absolute linearity Detector element has no contact with the measuring gas: can be used under harsh conditions, long service life
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.