Input delay: 5 ms
Primary and secondary side of the out and inputs are separated by optic couplers.
For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Performance Data
Supply voltage -
+24 V DC (+18-30 V DC)
Voltage monitor -
Yes
Galvanic isolation -
Yes
Input voltage -
+24 V DC (+18-30 V DC)
Input current -
3.7 mA at +24 V DC
Input delay -
typically 5 ms
Features -
inputs separated by optic couplers
Short-circuit proof, current limited -
Yes
Galvanic isolation -
Yes
Max. load current/channel -
1.7 A
Max. total current -
6.8 A to 10.2 A (temperature-dependent)
Mechanical Features
Dimensions -
12.5 x 104 x 72 mm (W x H x D)
Standardization/certification -
UL 508 (E247993)