The high voltage at both emitter points of the HE air nozzle is current limited. Being installed outside the air flow, the high-voltage points are hardly subject to fouling, if at all. The single point nozzle blowoff force is high at a relatively low air consumption. A Simco-Ion power unit supply the high voltage necessary for operation.
Modular
Compact
Low air consumption
Mutiple nozzles on 1 cable
Working distance: 250 mm max.
Air consumption: 3,5 Nm3/h using 1 bar
Shockless touchable emitters
Being installed outside the air flow, the emitter pins are hardly subject to fouling, if at all
Can be fitted on a standard air header
Click system for easy assembly
Working distance
250 mm
Housing material
plastic
Ionisation point
special alloy
Cable
PVC and PE
Weight
0,04 kg
Use circumstances
Industrial
Operating voltage
7 kV AC
Noise level
66 dB using 1 bar (at 1 metre)
Air consumption
3,5 Nm3/h using 1 bar
Max. pressure
7 bar
1/8” BSPT on nozzle
Option
multiple nozzles on header
Suitable power unit
A2A7S