With sheathed thermocouples SCT300, the flexible part of the probe is a mineral insulated cable. This cable consists of a stainless steel outer sheath, in which the inner conductors are encased for insulation and compressed into a highly compacted ceramic mass. The outer sheath is made of stainless steel or Ni alloy. The inner conductors are welded together at the measuring end of the sheathed cable to form the thermocouple. In designs where the measuring element is not insulated the sheath is also welded to the thermocouple. Connector cables are connected to the other end of the sheathed Üable, the sheathed cable is hermetically sealed with a sealing compound. The connector wires form the basis for the electrical interface, with cable, a connector or a terminal block then attached to these connector wires.
Application areas:
general machinery and equipment design
measuring temperature of liquids, gases and solid bodies
all branches of industry
Specification
Sheath -
any maximum length
nickel alloy 2.4816 (Inconel 600)
Accuracy -
II class
I class