• Version: Without start switch
• Test voltage: Contour / connection: 25,000 VDC
• Max. Operating voltage: 10,000 VDC / 8,000 VAC
The most important procedure in all safety tests is the high-voltage test. This test is very often carried out manually, with the safety test probe forming the link between the person, the high-voltage test device and the DUT. It is intended to safely contact the high voltage, but also to protect the person from life-threatening contact with the high voltage.
The SP 02 and SP 03 safety test probes fully meet these requirements. In addition, great importance was attached to the ergonomics and handling of the probes. Especially when testing hundreds of times a day, this point plays a decisive role in test comfort and therefore also test safety. The high-voltage test probes from SPS electronic are available with or without a start switch and with different cable lengths.