• Ex zone 0 and 20
• Stainless steel enclosure
• Flush or non-flush mounting
• Long life, no mechanical wear
• Suitable for the food processing industry
• Insensitive to soiling
• With LED
• M30 x 1.5 thread
• With pre-wired cable
• Attention: Please state required international approvals with your order!
Applied standards
EN IEC 60079-0, EN 60079-11, EN 60079-26
Enclosure
stainless steel 1.4305
Front cap
polycarbonate
Degree of protection
IP66, IP67, IP68 (EN 60079-0 + IEC/EN 60529)
Connection
cable PUR blue
Cable diameter
4.5 mm
Cable cross-section
2 x 0.5 mm²
Switching system
Namur to EN 60947-5-6
Correction factors
Steel (Fe360) = 1; Stainless steel approx. 0.7; Brass approx. 0.5; Aluminium approx. 0.4; Copper approx. 0.4
Rated operating voltage range UB
8.2 VDC
Current absorption
in presence of metal ≤ 1 mA; in absence of metal ≥ 3 mA
Switching frequency
500 Hz
Repeatability
≤ 3 %
Protection circuit
Inductive interference protection, protection against polarity reversal, short-circuit and overload proof
Ex marking
L II 1G Ex ia IIB T6 Ga,
L II 1D Ex ia IIIC T85°C Da