• Metal enclosure
• M8 x 1 thread
• Non-flush mounting
• To be connected to RF 96 ST or RF I/O universal transmitter
• With M12 coupling, 4-pole
Applied standards
EN 60947-5-2, EN 61000-6-2, EN 61000-6-3
Enclosure
stainless steel
Actuator
steel plate 8 x 8 x 1 mm, FE 360
Front cap
POM
Back cap
POM
Degree of protection
IP67 (IEC/EN 60529)
Connection
Coupling M12 x 1, 4-pole, A-coded
Cable length
0.5 m, 1 m or 2 m
Rated insulation voltage Ui
75 VDC
Rated operating current Ie
0.2 mA
Rated operating voltage Ue
3 … 5 VDC
Hysteresis
approx. 10 %
Repeatability
≤ 5 %
Type of installation
non-flush
Switching frequency
see RF 96 ST / RF I/O
Correction factors
Steel (Fe360) = 1; Stainless steel approx. 0.7; Brass approx. 0.5; Aluminium approx. 0.4; Copper approx. 0.4