• Thermoplastic enclosure
Applied standards
EN ISO 13849-1, EN 60947-5-1
Enclosure
thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Actuator
plunger: brass
Tightening torque
enclosure mounting screws: approx. 1 Nm
cover screws: approx. 0.6 Nm
Degree of protection
IP30 (IEC/EN 60529)
B10d (10 % load)
500 000 (R: 70 000 – with an actuating angle of 30°)
TM
max. 20 years
Degree of pollution
3
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact, type Zb
Connection
screw connection terminals
Cable cross-section
max. 1.5 mm²
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
400 V
Conventional thermal current Ithe
4 A
Rated operating current/voltage Ie/Ue
4 A/400 VAC
Utilisation category
AC-15
Short-circuit protection
4 A gG/gN fuse
Ambient temperature
–20 °C … +75 °C
Mechanical life
> 1 million operations (R: 70 000 operations – with an actuating angle of 30°)
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Contact opening
max. 2 x 4 mm