• Ex zone 1 and 21
• Metal enclosure
• 2 contacts
• Wire length up to 35 m
• Spring force variant: 100 N
• Compact design
• Release by push button (VD)
• Wire pull and breakage detection
• Watertight collar W for protection against penetration of dirt
• Position indicator A available
• Attention: Please state required international approvals with your order!
Applied standards
EN 60947-5-1, EN 60947-5-5, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13850, EN ISO 13849-1
Enclosure
aluminium die-cast, powder-coated
Cover
thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Degree of protection
IP65 (IEC/EN 60529)
B10d (10 % load)
200 000
TM
max. 20 years
Switch insert
1 x Ex 14
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact or 2 NC contacts, type Zb
Connection
pre-wired cable H05VV-F
Cable length
3 m
Cable cross-section
4 x 0.75 mm² (incl. conductor ferrules)
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
T6: 6 A, T5: 3 A
Utilisation category
AC-15; DC-13
Short-circuit protection
6 A gG/gN fuse
Mechanical life
> 100 000 operations
Max. wire length
35 m
Impact energy
max. 7 J
Ex marking
L II 2G Ex d IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex d IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db