The F02 has been designed for application in systems which require a pressure transmitter with a Performance Level PL d or a Safety Integrity Level of SIL 2. It is based on the tried and tested pressure transmitter type M01, and also has a thin-film measurement cell made from stainless steel which is welded together with the pressure sensor and thus guarantees high media compatibility.
The F02 is available within pressure ranges from 10 bar to 1200 bar. The output signal is made available at two outputs in parallel, whereby the second output represents an inverted signal. Users can select between a ratiometric and an 4-20-mA output in three-wire technology. The maximum permitted media temperature range extends from -40…+125 °C. The total accuracy in the compensated range of 0…+80 °C lies at <= 1 % FS. The maximum possible flexibility during integration into an existing machine is ensured through the provision of a multitude of available pressure connections as well as the small construction.The electrical contact takes place either via a 5-pole M12 or a Deutsch DT04 connector. The F02 also has E1 approval.