SUP-DO7013 Electrochemical dissolved oxygen sensor is widely used in Aquaculture, water quality testing, informational data collection, IoT water quality testing etc.
Features
Range: 0-20mg/L
Resolution: 0.01mg/L
Specification
Measurement - DO value in water
Measure range - 0~40.00mg/l
Resolution - 0.01mg/l
Temperature range - -20~60°C
Type of sensor - Galvanic Cell sensor
Measuring accuracy - <0.5mg/l
Communication protocol - Compatible with standard MODBUS-RTU protocol
ID - 1~255 Default ID 01 (0x01)
Fixing method - RS485 remote setting calibration and parameters
Power supply mode - 12VDC
Power consumption - 30 mA @12VDC
Intelligent module communication protocol Introduction
Communication port: RS485
Port setting: 9600,N,8,1 (by default)
Device address: 0x01 (by default)
Protocol specifications: Modbus RTU
Commands support: 0x03 read register
0X06 write register| 0x10 continuous write register