We will have to use the LKSDOME Ultrasonic generator in combination with the LEAKSHOOTER LKS1000V2 for tightness testings. What would be the best settings?
Answer
The best settings would be :
Use your LEAKSHOOTER LKS1000V2 with the standard cone, no flexible probe, and set the frequency mixer at 41.5 KHz.