The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.
The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.
Features
Ranges: 0-50 ppb to 0-10 ppm H2S and up to 20 ppm SO2, user selectable
Independent ranges and auto ranging
Large, vivid, and durable color graphics display with touch screen interface
Ethernet, RS-232, and (optional) USB com ports
Front panel USB connections for peripheral devices and firmware upgrades
8 analog inputs (optional)
Adaptive signal filtering optimizes response time
Temperature & pressure compensation
Auto zero system
Comprehensive internal data logging with programmable averaging periods
Ability to log virtually any operating parameter
Two-year warranty