Class II containment isolator HC-IS Series
transferfloor-standingnegative pressure

Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure - image - 2
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure - image - 3
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure - image - 4
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure - image - 5
Class II containment isolator - HC-IS Series - Tema Sinergie S.p.A. - transfer / floor-standing / negative pressure - image - 6
Add to favorites
Compare this product
 

Characteristics

Class
class II
Applications
transfer
Configuration
floor-standing
Other characteristics
negative pressure, positive pressure

Description

GMP Class 2 containment enclosure designed for the most challenging containment levels during manipulations of High Potent Active Pharmaceutical Ingredients (HPAPI) for compounding activities. MAXIMUM SAFETY Maximizing operator protection is the primary characteristic of a containment isolator. Tema Sinergie assures very stringent containment levels thanks to a perfect combination of design and manufacturing strategies. The system is equipped with inflatable and/or static seals made of FDA approved EPDM (Ethylene Propylene Diene Monomer) to guarantee air tightness Class II (ISO 10648:2). Turbulent air flow system, negative pressure gradient between the chambers and the lab environment. The high air quality of the isolated environment is assured by High Efficiency Particulate Air (HEPA H14) filters. ISOLATOR CONFIGURATION The isolator configuration is composed of a 4-glove working chamber and an inlet/outlet transfer chamber. AUTOMATIC LEAK TEST The Compounding Isolator (Production) is equipped with a routine automatic leak testing system which performs an independent leak test cycle for each chamber according to the pressure change method (5.2) ISO 10648-2 (E). GLOVE INTEGRITY TESTING The Compounding Isolator (Production) can be equipped with an integrated Automatic Glove Leak Testing System (AGLTS) which performs an independent leak test cycle for each glove mounted on the isolator system according to the Positive Pressure Decay Method described in the international standard ISO 14644-7 Annex E.5. Wireless Wi-Fi data transmission based on a TCP/IP protocol. Recognition of the glove to be tested by means of Radio Frequency IDentification (RFID) Technology.