• Analysis for thermal profile and thermal distribution.
• 8 input temperature measurement/data logging (°C/°F)
• Graphic display of overail trend for each input
• 4.5” STN LCD (240 x 128) with backlight
• Timers for the du rations out of HI and LO limits
• Selection of 11 types of thermocouple (K, J, E, T, R, S, N,...)
• Easy socket for thermocouple mini connector
• Basic accu racy O.1% ± 1 °C (K type)
• Programmable Hi-Lo alarm for each input.
• Display of max and min values for each input
• Sampling Rate 8 Inputs / 1 second
• 24 Hour Recording with Aikaline Batteries of 2400mAH
• Standard 2G SD memory card (stores 3.8-year data)
• Optional 8G SDHC memory card
• SD card directly read by PC
• Easy data file management (Read and Delete functions)
• Built-in calendar dock
• Independent Input Setup (type of thermocouple, Hi-Lo
• Isolated Input Protection of 35OVp-p between any two alarm values, name of Engineering Unit)inputs
• Programmable Engineering Unit (EU.) to integrate Analog Output (-50 to 60 mV) from instruments (e.g. Sound level meter, Humidity meter, Current adaptor)
• Screen hardcopy into files
• Paperless Recorder
• Ready to use package (Thermocouples, Memory Card, and Batteries etc.)