Pendulum humidity and temperature sensor LP+ active
relativeabsoluteenclosed

Pendulum humidity and temperature sensor - LP+ active - Thermokon Sensortechnik - relative / absolute / enclosed
Pendulum humidity and temperature sensor - LP+ active - Thermokon Sensortechnik - relative / absolute / enclosed
Pendulum humidity and temperature sensor - LP+ active - Thermokon Sensortechnik - relative / absolute / enclosed - image - 2
Add to favorites
Compare this product

Characteristics

Type
relative, absolute
Mounting
enclosed
Technology
infrared, NDIR
Output
digital, 0-10 V, 0-5 V
Supply voltage
24 Vdc, 15VDC, 32VDC
Electrical connection
terminal block
Protection level
IP65, IP20
Other characteristics
CO2, pendulum
Applications
for indoor air
Measuring range (%)

Max.: 100 %

Min.: 0 %

Precision

2 %

Measuring range (temperature)

Max.: 50 °C
(122 °F)

Min.: 0 °C
(32 °F)

Accuracy (temperature)

0.5 °C
(32.9 °F)

Working temperature

Max.: 50 °C
(122 °F)

Min.: 0 °C
(32 °F)

Description

Room pendulum sensor for measuring CO2 in large rooms (exhibition halls, factories, museums etc.). The LP+ comes with an analogue 0..10 V output for connecting to a BMS or monitoring system. • Application/type : Pendulum sensor, Room sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point, CO2 • Interface : Active, 0..5 V, 0..10 V • Configuration : USEapp, uConfig, jumper • Sensor : integrated digital temperature transmitter, NDIR (non-dispersive, infrared) • Output voltage : 2x 0..10 V or 0..5 V, 3x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,5 K (typ. at 21 °C) • Measuring range humidity : 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, optionally configurable • Accuracy humidity : ±2% between 10..90% rH (typ. at 21 °C), offset setting via app or uConfig • Measuring range CO2 : 0..2000 ppm, 0..5000 ppm, optionally configurable • Accuracy CO2 : ±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel • Power supply : 15..35 V = SELV, 19..29 V ~ SELV • Power consumption : max. 2,5 W (24 V =), 4,3 VA (24 V ~) • Material in touch with media : Sensor head, black, length 126 mm • Display : LCD 29x35 mm, RGB backlight, with traffic light function, threshold values configurable, optionally configurable via app or uConfig • Enclosure : USE-M, impact- and shock-resistant enclosure with quick-release cover, PC

Catalogs

Products
Products
428 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ISH 2025
ISH 2025

17-21 Mar 2025 Frankfurt am Main (Germany) Hall 11.1 - Stand D55

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.