HVAC temperature sensor TF25+ active
with housing4-20 mA0-10 V

HVAC temperature sensor - TF25+ active - Thermokon Sensortechnik - with housing / 4-20 mA / 0-10 V
HVAC temperature sensor - TF25+ active - Thermokon Sensortechnik - with housing / 4-20 mA / 0-10 V
HVAC temperature sensor - TF25+ active - Thermokon Sensortechnik - with housing / 4-20 mA / 0-10 V - image - 2
HVAC temperature sensor - TF25+ active - Thermokon Sensortechnik - with housing / 4-20 mA / 0-10 V - image - 3
Add to favorites
Compare this product

Characteristics

Mounting
with housing
Output
4-20 mA, 0-10 V, 0-5 V
Electrical connection
terminal block
Protection level
IP65, IP67
Applications
high-temperature, for liquids, HVAC, for refrigeration circuits
Other characteristics
precision, with thermowell
Temperature

Max.: 250 °C
(482 °F)

Min.: -50 °C
(-58 °F)

Probe diameter

6 mm
(0.2 in)

Description

Cable sensor for temperature measurement in HVAC or refrigeration applications. In combination with a thermowell, the TF25 can also be used for temperature measurement in liquid media. Depending on the application requirements, different PVC, silicone, high-temperature silicone and fibreglass cables are available. • Application/type : Cable sensor • Purpose : Measure values • Measured values : temperature • Interface : Active, 0..5 V, 0..10 V, 4..20 mA, Switch contact • Configuration : USEapp, uConfig, BUS, jumper, DIP switches, (depending on type) • Sensor : SI-Protection against permeation of humidity and mechanical stress (e.g. vibration) • Output voltage : 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 5 kΩ, min. load 10 kΩ • Output current : 4..20 mA, max. load 500 Ω • Output switch contact : 2x floating contact NO for 24 V ~ or 24 V = / 3 A • Operating range temperature (°C) : -50..+250 • Operating ranges temperature (°C) : -50..+160, -50..+180, -50..+250 • Output signal temperature : scaling analogue output, 0..+160 °C (default setting), selectable from 4 temperature ranges -50..+50 | -20..+80 | -15..+35 | -10..+120 | 0..+50 | 0..+100 | 0..+160 | 0..+250 °C, adjustable at the transducer, optionally configurable via app or uConfig • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,5 K (typ. at 21 °C), within default measuring range, potentiometer for offset adjustment, offset setting via app or uConfig • Power supply : 15..24 V = (±10%) SELV, 15..35 V = SELV, 24 V ~ (±10%) SELV, 19..29 V ~ SELV

Catalogs

Products
Products
428 Pages
Products 2018
Products 2018
460 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ISH 2025
ISH 2025

17-21 Mar 2025 Frankfurt am Main (Germany) Hall 11.1 - Stand D55

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.