Air duct humidity and temperature sensor FTK+ active
relativeabsoluteflange-mount

Air duct humidity and temperature sensor - FTK+ active - Thermokon Sensortechnik - relative / absolute / flange-mount
Air duct humidity and temperature sensor - FTK+ active - Thermokon Sensortechnik - relative / absolute / flange-mount
Air duct humidity and temperature sensor - FTK+ active - Thermokon Sensortechnik - relative / absolute / flange-mount - image - 2
Air duct humidity and temperature sensor - FTK+ active - Thermokon Sensortechnik - relative / absolute / flange-mount - image - 3
Air duct humidity and temperature sensor - FTK+ active - Thermokon Sensortechnik - relative / absolute / flange-mount - image - 4
Add to favorites
Compare this product

Characteristics

Type
relative, absolute
Mounting
duct-mount, flange-mount
Technology
dew-point, Pt100, Pt1000
Output
4-20 mA, 0-10 V, 0-5 V
Supply voltage
24 Vdc, 15VDC, 32VDC
Electrical connection
terminal block
Protection level
IP65
Other characteristics
with integrated digital display
Applications
air, gas, air duct
Measuring range (%)

Max.: 100 %

Min.: 0 %

Precision

2 %

Measuring range (temperature)

Max.: 80 °C
(176 °F)

Min.: -40 °C
(-40 °F)

Accuracy (temperature)

0.3 °C
(32.54 °F)

Working temperature

Max.: 70 °C
(158 °F)

Min.: -20 °C
(-4 °F)

Description

Duct sensor for measuring relative and absolute humidity, enthalpy, dew point and temperature in gaseous media of heating, ventilation and air-conditioning systems as well as clean rooms. The optional features, such as relay outputs for 2-point controllers or 2-stage 2-point controllers and color-changing LCD allow for a wide range of applications. The accuracy of the humidity sensor is 2%. A hinged cover and tool-free wiring as well as removable cable entries ensure a quick and easy installation. • Application/type : Duct sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point • Interface : Passive, Active, 0..5 V, 0..10 V, 4..20 mA, Switch contact • Configuration : USEapp, uConfig, jumper • Sensor : Pt1000 DIN cl. B, Pt100 DIN cl. B, Pt1000 1/3 DIN, Pt100 1/3 DIN, Ni1000 DIN cl. B, Ni1000TK5000, NTC10k, NTC10k Precon, NTC20k, NTC1,8k, NTC5k, LM235Z, additional passive sensor • Output voltage : 2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Output current : 2x 4..20 mA, max. load 500 Ω • Output switch contact : 2x floating contact NO for 24 V ~ or 24 V = / 3 A • Operating range temperature (°C) : -20..+70 • Output signal temperature : scaling analogue output, -20..+80 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, adjustable at the transducer, optionally configurable, depending on used sensor • Operating range humidity : max. 85% rH short term condensation

Catalogs

Products
Products
428 Pages
Products 2018
Products 2018
460 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ISH 2025
ISH 2025

17-21 Mar 2025 Frankfurt am Main (Germany) Hall 11.1 - Stand D55

  • More information

    Other Thermokon Sensortechnik products

    Duct Application

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.