Relative humidity and temperature sensor FTK+ RS485 BACnet
absoluteflange-mountdewpoint

Relative humidity and temperature sensor - FTK+ RS485 BACnet - Thermokon Sensortechnik - absolute / flange-mount / dewpoint
Relative humidity and temperature sensor - FTK+ RS485 BACnet - Thermokon Sensortechnik - absolute / flange-mount / dewpoint
Add to favorites
Compare this product

Characteristics

Type
relative, absolute
Mounting
flange-mount
Technology
dewpoint
Output
RS-485, 0-10 V, 0-5 V
Supply voltage
24 Vdc, 15VDC, 32VDC
Electrical connection
terminal block
Protection level
IP65
Other characteristics
with integrated digital display
Applications
for air conditioning, for clean rooms, air duct
Measuring range (%)

Min.: 0 %

Max.: 100 %

Precision

2 %

Measuring range (temperature)

Min.: -40 °C
(-40 °F)

Max.: 80 °C
(176 °F)

Working temperature

Min.: -20 °C
(-4 °F)

Max.: 70 °C
(158 °F)

Description

Duct sensor for measuring relative and absolute humidity, enthalpy, dew point and temperature in gaseous media of heating, ventilation and air-conditioning systems as well as clean rooms. The optional features, such as relay outputs for 2-point controllers or 2-stage 2-point controllers and color-changing LCD allow for a wide range of applications. The accuracy of the humidity sensor is 2%. A hinged cover and tool-free wiring as well as removable cable entries ensure a quick and easy installation. • Application/type : Duct sensor • Purpose : Measure values • Measured values : temperature, relative humidity, absolute humidity, enthalpy, dew point • Interface : RS485 BACnet, Active, 0..5 V, 0..10 V • Configuration : USEapp, uConfig, BUS, jumper, DIP switches • Output voltage : 2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Network technology : RS485 BACnet (MS/TP) • Output signal temperature : scaling analogue output, -20..+80 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,3 K (typ. at 21 °C), within default measuring range, offset setting via app or uConfig • Measuring range humidity : 0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, optionally configurable • Accuracy humidity : ±2% between 10..90% rH (typ. at 21 °C), offset setting via app or uConfig • Power supply : 15..35 V = SELV, 19..29 V ~ SELV

Catalogs

Products
Products
428 Pages
Products 2018
Products 2018
460 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ISH 2025
ISH 2025

17-21 Mar 2025 Frankfurt am Main (Germany) Hall 11.1 - Stand D55

  • More information

    Other Thermokon Sensortechnik products

    Duct Application

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.