Air duct temperature sensor AKF10+ LON
resistanceductflange

Air duct temperature sensor - AKF10+ LON - Thermokon Sensortechnik - resistance / duct / flange
Air duct temperature sensor - AKF10+ LON - Thermokon Sensortechnik - resistance / duct / flange
Air duct temperature sensor - AKF10+ LON - Thermokon Sensortechnik - resistance / duct / flange - image - 2
Add to favorites
Compare this product

Characteristics

Technology
resistance
Mounting
flange, duct
Output
0-10 V, 0-5 V
Electrical connection
terminal block
Protection level
IP65
Applications
for gas, air, air duct
Other characteristics
with thermowell, with digital display
Temperature

Min.: -50 °C
(-58 °F)

Max.: 250 °C
(482 °F)

Probe diameter

6 mm
(0.2 in)

Description

Duct sensor for measuring air temperature and other gaseous media (e.g. in ventilation and air conditioning systems). Combined with a thermowell pocket, it can be used as an immersion temperature sensor as well. Models with a relay output for a 2-point controller or a 2-stage 2-point controller and color-changing LCD allow for a wide range of applications. A hinged cover and tool-free wiring as well as removable cable entries ensure a quick and easy installation. • Application/type : Duct sensor, Immersion sensor • Purpose : Measure values • Measured values : temperature • Interface : LON FT, Active, 0..5 V, 0..10 V • Configuration : USEapp, uConfig, BUS, jumper, DIP switches • Sensor : SI-Protection against permeation of humidity and mechanical stress (e.g. vibration) • Output voltage : 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ • Network technology : LON FT (free topology) • Operating range temperature (°C) : -50..+160 • Operating ranges temperature (°C) : -50..+160 • Output signal temperature : scaling analogue output, 0..+160 °C (default setting), -20..+80 °C (default setting), selectable from 4 temperature ranges -50..+50 | -20..+80 | -15..+35 | -10..+120 | 0..+50 | 0..+100 | 0..+160 | 0..+250 °C, optionally configurable • Operating range temperature enclosure (°C) : -30..+70, -20..+70 • Operating range humidity : max. 85% rH short term condensation • Accuracy temperature : ±0,5 K (typ. at 21 °C), within default measuring range, offset setting via app or uConfig • Power supply : 15..35 V = SELV, 19..29 V ~ SELV • Power consumption : max. 2,5 W (24 V =), 4,3 VA (24 V ~)

Catalogs

No catalogs are available for this product.

See all of Thermokon Sensortechnik‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ISH 2025
ISH 2025

17-21 Mar 2025 Frankfurt am Main (Germany) Hall 11.1 - Stand D55

  • More information

    Other Thermokon Sensortechnik products

    Duct Application

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.