• Specified by Texas Instruments in Reference Design SLUU341 for 300 Watt Isolated PFC Power Supply
• EF20-1, Flyback transformer (T201) for 5 W bias supply operates with an input voltage range of 100 - 450 V.
• EF20-1, Gate drive transformer (T301)
Core material Ferrite
Terminations RoHS compliant tin-silver over tin over copper. Other terminations available at additional cost.
Weight EF20-1:13.5 g;
Ambient température -40°C to +85°C Storage température Component: -40°C to +85°C.
Tray packaging: -40°C to +80°C
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C / 85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332 Packaging 100 per tray
PCB washing Tested with pure water or alcohol only. For other solvents, see Doc787_PCB_Washing.pdf.
1. Inductance measured at 100 kHz, 0.1 Vrms, 0 Adc using an Agilent/
HP 4263B impédance analyzer or équivalent.
2. Peak primary current drawn at minimum input voltage.
3. Leakage inductance is for the primary and is measured with the second-ary shorted.
4. Output of the P1 winding is 10 V, 20 mA.
5. Isolation: 3000 Vrms, one minute primary to secondary;
500 Vrms, one minute windings to core
6. Electrical spécifications at 25°C.