ZWIN-PM08 particulate sensor is a new type of intelligent sensor mainly used for online monitoring of particulate matter(PM10,PM2.5,TSP) . It is capable of monitoring TSP, PM2.5, PM10 and other particulate matter parameters. It adopts the principle of light scattering, the system cleverly designs the light sensitive area as the source of particle scattering. When the particles pass through the photosensitive area formed by the focused laser, the light scattered by the particles is collected by the micro-photodetector on the detection window, and the micro-photodetector quickly and accurately converts the received light intensity signal into an equivalent voltage signal , the intensity of the signal corresponds to the unit concentration value of the particle, and the particle concentration value is output in real time through the data interface after coefficient conversion.
The sensor is equipped with RS485 signal transmission interface, which is easy to operate, accurate in measurement and reliable in operation. It can be embedded in various instruments related to the detection of particle concentration, and is suitable for monitoring of dust particles in construction sites, roads and areas with serious pollution.
Monitoring principle: light scattering principle
PM2.5 measurement range/resolution: 0-10000/0.1ug/m3
PM10 measurement range/resolution: 0-10000/0.1ug/m3
TSP measurement range/resolution: 0-30000/1ug/m3
Response time: 1 s
Power supply voltage: DC12V
Smart sensors, mainly monitorsTSP, PM2.5, PM10 and other particulate matter parameters
Sampling method: pump suction
Output mode: RS485