Main functions
Display of time received in an Ethernet
frame or an IRIGB12x signal.
Automatic selection of the available
time source
Display of 3 types of time code: UT, CD
or H0
This multi protocol display is able to
receive, process and display a time UT
/ CD / H0 received in one of two
formats:
• Digital Ethernet (IP protocol)
• IRIG-B UT / CD / H0
Display
The display consists of six 20 mm 7
segment digits for the time as HH: MM:
SS and 4x20 mm 16 segments digits for:
• the day of the year or type "UT", "CD"
or "H0"
• failure marker "*"
• + or - for the CD
To be functional, the display must be
connected to 230V AC and have at
least one of the time sources:
• IP frame: network link, standard CAT5
cable with RJ45 plug.
• IRIG B Signal (UT, CD or H0): analog
modulated signal, coax BNC or twisted
pair cabling on BR2 connector.
Parameters setting
The setting of the display is done via a
serial link. The link "Console" allows
direct connection to a PC.
The display has an automatic
operation which depends on the
programmed configuration.
This configuration is stored in nonvolatile EEPROM memory. It is restored
when switching on the display.
Brightness is adjustable by a rotary
encoder. It may also be done remotely
by the console link.