The ABP 115 filter test rig performs tests according to guideline ISO 5011 (test of inlet air cleaners). Results are:
- Differential pressure related to air flow rate Druckverlust über dem Filter,
- Dust loading capacity (related to differential pressure increase, e.g. 20 hPa),
- Gravimetric efficiency,
- Differential pressure of filter.
Considering new discussions on additions to the standard also
- Particle measurement,
- Downstream dust concentration ,
- Fractional efficiency,
- Water tests
can be done. The filter element will be mounted in the filter housing and connected to the filter test system. The ambient air will be sucked in at desired flow rates and the dust feeder disperses the test dust. Differential pressure increase and separation efficiency will be obtained.