While can coating the time-temperature cycle must be controlled carefully – Together with the cans the oven recorder winds through the conveying system in the oven and makes up a complete temperature profile. With help of paint cure specifications it determines the curing process by calculating the cure index for you, enabling a simple pass / fail setup. From a computer, you can analyse all gathered data with TQC Ideal Finish Analysis software and print a report with all measurement data and graphs.
4-Channels
The CurveX 3 Nano has four thermocouple type K inputs to be used to measure either surface- or air temperature. The CurveX 3 Nano comes complete with 4 wire probes and self-adhesive attachment pads to position the probes. Each probe can be used for either surface or air temperature. The probes are usually attached to a real can on the next pin.
Housing
The CurveX 3 Nano is built into a stainless steel casing and has a can shaped form factor. This form factor allows the data logger to be used in a variety of can oven setups. Usually the cans traverse through the production process by placing them over pins, the pins in turn are attached to a big chain that runs through the whole production line. The housing at the same time functions as insulation box. Unlike our other CurveX products the Nano does not need a separate insulation box.
Inside end-caps