IV-20
.Module with Incremental-Encoderconnection (K0, /K0, K1, /K1, K2, /K2)
.Four operating modes for adaptation to the signal source
.Six output channels with adjustable output levels (5VDC, 11-30VDC)
Electrical Data
Operating Voltage ..................................................... 11-30 V DC
Reverse Battery Protection ....................................... yes
Transient Voltage Protection ..................................... ESD
Excess Current Release ........................................... VDE 0113
Filter Groups ............................................................. IEC 1000-4-x
Power Dissipation (No Load) .................................... < 4 Watt
Min./Max. Input Current per Trace ............................ 1,5mA / 20mA (diode current Optocoupler)
IV-30
.Module with Incremental-Encoder-
Connection
- 5V differential, 493-00100
- 24V single-phase, 493-00101
.All inputs and outputs of the signals galvanically isolated
.Six output channels with adjustable output levels (RS422, 11-29V)
Electrical Data
Operating Voltage ..................................................... 24 V DC 20%
Reverse Battery Protection ....................................... yes
Transient Voltage Protection ..................................... ESD
Excess Current Release ........................................... VDE 0113
Filter Groups ............................................................. IEC 1000-4-x
Current Consumption (without Encoder, Load) ......... approx. 120mA
Min./Max. Input Current per Channel ........................ 1,5mA / 20mA (diode current Optocoupler)