The TFV 900 Ex radial fan has special features packed into it like unique coupling elements for the models that comply with the ATEX regulations and that are permitted to be used in zones 1 and 2 and zones 21 and 22. The air is blown out of the fan at a rate of 33600m3/h at a pressure of 1900 Pa. The air is discharged at a speed of 34 m/s.
The fan has only one stage where the maximum temperature of the air attained is 60ºC. The power required for the fan is an input voltage of 400V at 50Hz. It has in-built protection from currents of to 63 A.
Technical data TFV 900 EX:
Free discharge air volume: 33,600 m³/h
Air discharge speed: 34 m/s (122.4 km/h)
Fan stages: 1
Air pressure max.: 1,900 Pa
Max. transport medium temperature: 60 °C
Surrounding conditions: -20 °C to 40 °C
Input voltage: 400 V / 50 Hz (36 A)
Power input: 18.5 kW
Intake duct: accesories (ø 630 mm)
Outlet duct: standard (ø 630 mm)
Sound level (distance 1.5 m): 82 dB (A)
Housing: steel, powder-coated, 2K paint
Dimensions (with frame): 1,950 x 1,900 x 2,200 mm
Weight: 450 kg
Ex class: II3G, zone 2, T4