●4..20 mA two-wire pressure transducer
●Ceramic cell made from Al2O3
●Pressure cell protected from mechanical damage
●Infinitely adjustably rotatable cable outlet for clean alignment
Characteristics
The EPS1 pressure transformer measures static and dynamic pressures in fluids and gases. The robust 100% metal construction makes it suitable for universal industrial use.
The pressure transformer consists of a measuring cell (four extension measurement cells using thick film technology applied to a ceramic substrate) and the converter / counter. This converts the bridge signal into a pressure-proportional 4..20 mA signal. The pressure cell is connected to the medium via a drilling with 8 mm diameter, and this construction protects it securely from mechanical damage.
Handling and operation
Installation
The pressure transformers are screwed into a nozzle or a T-piece in the pipework, using a suitable sealing material (e.g. Klingerit). The installation of the pressure sensor should result in no significant reduction of the cross-section of the pipework. When tightening the pressure sensor, use only the hexagonal spanner (SW27) specifically provided.
Avoid installation locations with high pressure surges (see overload limits).
In the high temperature model with flexible gooseneck, the pressure transformer can be operated up to a media temperature of 120 °C.
Accessories
●Cable/round plug connector (K04…, KB04...) see additional information “Accessories”
●converter OMNI-TA