Capacitive double rod electrode for level measurement
Double rod probe, fully FEP insulated
Application area
For use in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant. A full/empty adjustment is necessary for setup.
The VEGACAL 69 is a level sensor for continuous level measurement of liquids in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant.
Your benefit
Low mounting expenditure through compact double rod version
Long service life and low maintenance due to high resistance materials
Maximum utilization of the vessel because measurement over the complete probe length
Measuring range - Distance
4 m
Process temperature
-50 ... 100 °C
Process pressure
1 ... 2 bar
Version
FEP insulation
Materials, wetted parts
PTFE
PP
FEP
Flange connection
≥ DN50, ≥ 2"
Seal material
no media contact
Housing material
Plastic
Protection rating
IP66/IP67
Output
Profibus PA
Foundation Fieldbus
4 … 20 mA/HART - two-wire
Ambient temperature
-40 ... 80 °C
Explosion protection
Intrinsic safety Ex ia
SIL qualification
SIL2
Adjustment
PLICSCOM
PC, PACTware and DTM
HART-Communicator
Software (e. g. AMS™, PDM)