-Microwave induced Sterilization Process (Optional)
-Pressure container built of high-quality Stainless Steel
-Design and production certified by TUV Austria
-Produced according to EU Directives PED (2014/68/EU) 2006/42/EC, 2014/30/EU & EU Norms EN285
-Sophisticated automation control system with advanced reporting and monitoring software
-Online access via the internet for supervision and troubleshooting
-Fully automatic operation- no need for any operator intervention
-Automatic elevator system for easy loading (Optional)
-No water consumption
-Low fuel and electrical consumption for integrated steam boilers equipped with state of the art steam regeneration system
-Vacuum Pump
-Odor Control System (Option
Loading
-
At the beginning of the cycle , once the upper lid opens, the operator loads the waste in the loading chamber.
Shredding / Microwave
The shredder, controlled by the PLC, changes rotation direction due to the “anti blocking” capability that prevents the blades to get jammed. Durring the shredding process the waste is treated with microwave generated by 6 integrated magnetron units (Optional)
Our special design shredder is capable of grinding very hard materials like surgical stainless steel instruments and hard ceramics.
Heating / Sterilization
Heating is achieved by injecting saturated steam until the homogeneous temperature in the upper and lower chamber reaches 134°C (274 F). Sterilization is completed by maintaining 134°C (274 F) - 138 °C (280 F) temperature and equivalent pressure for a period of 10 – 15 minutes.