A pressure transducer converts pressure in gasses or liquids into an analog electrical signal.
• Capacity (bar) : 50, 100, 200, 250, 350, 500, 700, 1000
• Accuracy : ±0.2 % FS
• Safe overload : 150 %
• Full load output : 2.0 nom. mV/V
• Zero balance : <±5.0%
• Repeatability : <0.10%
• Input resistance : 350Ω
• Output resistance : 350Ω
• Compensated temp. Range : -10 to 40 °C
• Operating temp. Rage : -20 to 60 °C
• Temp. Coefficient on zero : <0.040 % Capacity/°C
• Temp. Coefficient on span : <0.040 % Capacity/°C
• IP class : IP67
• Material : Stainless steel
Design
Robust stainless steel construction
Measurement
Economical pressure measurement
Resistant
To transients and spikes
Options
Other ranges and non-standard sizes available on request