Applications
For the air filtration in aerial engineering plants with dangerous, combustible atmospheres (mixtures from air and burnable gases or steams)
Application for
Gas-Ex-Protection εx || 2 GD (X)
Application for zones 1 and 2 also 21 or 22
The Ex-Protect-Filter was tested according to following norms: EN 1127-1, BGR 132/CENELEC Report R 044-001,
EN 13463-1 und EN 15198
Classification acc. to EN 779
Filter class G4 - white version1
Filter class M5 - brown version(white 1)
Filter class M6 - green version
Filter class F7 2 - pink version
Filter class F8 2 - yellow version
Filter class F9 2 - white version
Versions
Synthetic fibres with metal-clutch
Standard sizes stitched
With galvanized metalframe (inner and outer frame)
Available in three earthing versions:
with grounding flag
with grounding pin
without earthing
1) Polyester version - no 3-layer media
2) Tested accoeding to EN 779 2002
Material characteristics
Tested according to EN 779:2012
Shatter-proof synthetic fibres
umidity resistant up to 100% r. h
Temperature resistant up to max. 80°C depending on type of frame
Technical filter check conducted by TÜV Industrie Service GmbH acc. to Guideline 94/9/EG