Specifications
· Operating Pressure:350BAR
· Flow :150L/min
· Internal Leakage:5drop/min.max.at operating pressure
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity:16-2
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Efficient wet-armature construction
· Continuous-duty solenoid
· Compact size
Operation
When de-energized, the valve allows flow from ② to ① . Flow from ① to ②
is severely restricted in this mode.
When energized the valve’s poppet closes on its seat, blocking flow from
② to ① .The cartridge will allow ① to ② flow after overcoming the solenoid
force.