Specifications
· Operating Pressure:240BAR
· Flow:189L/min
· Internal Leakage:164ml/min.max.at operating pressure
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity:16-S3
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Compact size
· Low pressure loss
Operation
The valve is a spring-biased blocking valve which will shift to allow full flow
from ① to ② only when pressure at ① exceeds the cumulative pressure of ③,
plus the bias spring pressure value.
When no pressure at ③,flow will be allowed from ① to ② once the bias spring
force is overcome with pressure at ① .