Specifications
· Operating Pressure:250BAR
· Flow:20L/min
· Internal Leakage:164ml/min.max.at operating pressure
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity:10-5
· Fluids: Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Efficient wet-armature construction
· Continuous-duty solenoid
· Compact size
Operation
When de-energized, the valve blocks the remaining oil port ,
except allowing flow from port ① to port ②.
When coil S1 is energized, flow is allowed from ① to ③, and from
⑤ to ④,while blocking flow at port ②.
When coil S2 is energized, flow is allowed from ① to ⑤, and from
③ to ④, while blocking flow at port ②.